A Georgian townhouse can have generous proportions, original plasterwork and carefully restored joinery, yet still rely on a collection of light switches, heating timers, standalone alarms and separate entertainment controls. This KNX retrofit example shows how those systems can be brought together without treating a period home as if it were a blank new-build shell.

The objective is not to fill the property with visible technology. It is to make everyday living more comfortable and the home easier to manage, while protecting the architecture that made the property desirable in the first place. For a family home in London, that may mean lighting that responds properly to the time of day, heating that follows occupancy, discreet security, and simple controls that everyone understands.

The brief: better control without a full rewire

Consider a five-storey London townhouse undergoing a substantial interior refurbishment. The owners wanted to retain original ceiling details, refurbish timber panelling and avoid unnecessary disturbance to finished areas where possible. They also wanted to address familiar frustrations: too many switches, inconsistent lighting levels, heating running in unoccupied rooms, unreliable Wi-Fi and separate apps for audio, cameras and the alarm.

A conventional smart-home approach might add individual wireless products to each problem. That can be useful for a small upgrade, but it often creates a fragmented experience in a larger property. Different manufacturers, different interfaces and different support arrangements can leave the homeowner managing the technology rather than benefiting from it.

KNX offered a more considered route. It is a building-control standard designed to connect lighting, shading, heating, cooling, ventilation and selected security functions within one engineered system. In a retrofit, the question is not whether every circuit and device must be replaced. The right answer is usually a measured combination of retained infrastructure, targeted new cabling and carefully selected KNX components.

A KNX retrofit example, room by room

The entrance hall set the tone for the whole scheme. Instead of a row of conventional switches, a tailored keypad was installed beside the front door. One button provided a welcoming arrival setting, bringing on hall and stair lighting at a comfortable level. Another activated an evening route through the house. A final command put the property into an away mode, switching off selected lights, lowering heating setpoints and checking that designated security zones were armed.

The difference is not simply fewer buttons. Each control has a clear purpose, with engraving and finishes selected to suit the interior. Guests can still operate the lights intuitively, while the owners have useful whole-house functions without needing to reach for a phone.

Lighting that suits the architecture

In the principal reception rooms, existing decorative fittings were retained and supplemented with discreet architectural lighting. KNX dimming control allowed chandeliers, wall lights, picture lights and joinery lighting to work as composed scenes rather than isolated circuits. A daytime setting could emphasise natural light and artwork. In the evening, the room could shift to a warmer, lower level for dining or entertaining.

This is where retrofit design requires judgement. Not every original fitting will dim well, and not every lighting circuit needs costly replacement. Drivers, lamp compatibility and load types should be assessed early. In some cases, a retained fitting can be controlled perfectly. In others, changing a lamp or driver is the sensible decision to achieve stable, flicker-free dimming.

Occupancy sensing was used selectively rather than indiscriminately. It made sense in cloakrooms, utility spaces, circulation areas and secondary bathrooms. It would be less appropriate in a drawing room, where occupants may be sitting quietly and do not want lighting to respond mechanically. Good automation should feel attentive, not intrusive.

Climate control beyond a heating timer

The property had a mix of radiators, underfloor heating in the renovated kitchen and cooling in selected bedrooms. Left as separate systems, each would have required its own controller and programming logic. KNX enabled these systems to be coordinated around room use, time schedules and simple manual adjustment.

Individual room temperature control meant the nursery, bedrooms, kitchen and formal rooms could be managed differently. When the house entered away mode, heating could reduce automatically. Before the family returned from a weekend away, the home could be brought back to comfort levels without heating every room unnecessarily for days.

Energy efficiency is not achieved by automation alone. Fabric performance, boiler or heat-pump design, valve selection and commissioning all matter. However, sensible zoning and responsive control prevent common waste, particularly in large homes where rooms are not used evenly throughout the day.

Security, gates and informed responses

The brief also included CCTV, access control and integration with the existing intruder alarm. Rather than attempting to replace a reliable security system unnecessarily, the design allowed key status information to be presented through the main control interface. The owners could see whether the property was armed, check gate and door status, and receive a clear notification if a security event required attention.

At the gate, a visitor call could trigger a video intercom screen in the kitchen, principal bedroom and mobile control interface. Exterior lighting could be brought up when the gate was opened after dark. These responses need to be planned carefully. Security systems must remain dependable even if another part of the home technology system is being serviced, so appropriate interfaces and fallback operation are essential.

The infrastructure decision that makes retrofit work

A KNX installation is often described as wired automation, which can make homeowners assume it is unsuitable for an existing property. In practice, retrofit does not always mean opening every wall. During a renovation, there are usually opportunities to use floor voids, service risers, loft spaces, joinery runs and areas already being replastered.

In this project, new KNX cable was routed where building work gave access, particularly between the plant area, lighting-control locations and keypads. Existing electrical circuits were retained where they were safe and suitable. Centralised control equipment was housed in a properly ventilated, accessible technical area rather than scattered throughout the house.

Some wireless devices may have a place where access is genuinely limited, but they should be chosen as part of the wider design, not as a substitute for planning. A premium retrofit benefits from a dependable backbone. The same applies to the network system: Wi-Fi access points, switches and cabling need to be specified alongside the automation, AV and security systems. A beautiful control interface is of little value if the underlying network is inconsistent.

Controls should be clear before they are clever

The most successful part of this KNX retrofit example was not a particular touchscreen or feature. It was the decision to simplify the way the family interacted with the house. Keypads handled everyday room functions. Touchscreens provided a clear overview of lighting, climate, security and audio. Mobile control was available when away from home, but it was not the only means of operation.

This balance matters. A phone is convenient, yet physical controls remain faster at the door, beside the bed and in a busy kitchen. The system should also continue to behave sensibly if a tablet is charging, a mobile app needs updating or a guest is staying in the house.

Scene names were tailored to the household rather than imported from a generic template. “Breakfast”, “Family evening” and “Goodnight” are more useful than technical labels. During commissioning, each setting was adjusted in the actual rooms, with the clients present, so brightness levels, timing and temperature expectations reflected real life.

What to establish before specifying a KNX retrofit

The quality of the result depends on early coordination. Architects and interior designers need to know which keypad positions, sensor locations, speaker grilles, access points and equipment spaces are required before final finishes are fixed. Mechanical and electrical contractors need clear responsibilities for plant interfaces, cabling routes and containment.

The budget should also distinguish between essential infrastructure and optional enhancements. Lighting control, climate zoning, network resilience and security integration may form the core scope. Motorised blinds, whole-home audio, automated gates and advanced energy monitoring can then be considered according to the property and the client’s priorities.

MOSAIC Audio & Visual approaches this process as a coordinated building-technology design exercise, not a catalogue of individual products. That means considering the electrical installation, controls, network, AV and security together, then presenting the finished system in a way that feels calm and straightforward.

A retrofit does ask for compromise in places. Listed features, limited service routes, existing equipment and programme constraints all influence what is practical. Yet a well-planned KNX system does not need to announce itself through screens and gadgets. In the right property, it simply gives the home a more considered rhythm: the right light, the right temperature, secure arrival, and fewer decisions to make at the end of the day.